Low specificity of HIV-testing on sputum specimens kept at ambient temperatures for 4 to 7 days: a blinded comparison

dc.contributor.authorEgwaga, S.M
dc.contributor.authorChonde, T.M
dc.contributor.authorMatee, M.I
dc.contributor.authorMfinanga, S.G
dc.contributor.authorNgowi, P.E
dc.contributor.authorLwilla, F.
dc.contributor.authorCobelens, F.G.J.
dc.date.accessioned2013-02-13T13:17:34Z
dc.date.available2013-02-13T13:17:34Z
dc.date.issued2007
dc.description.abstractBackground: HIV testing on sputum using the QraQuick HIV1/2® assay has high sensitivity and specificity, and holds promise for application in tuberculosis surveys. Its performance under conditions that may occur during surveys in resource-poor countries is however, unknown. We assessed, in a blinded comparison with HIV serum testing, the sensitivity and specificity of the OraQuick® assay for detecting HIV antibody in sputum specimens kept at ambient temperature for up to 7 days, with and without decontaminant. Methods: Paired sputum and blood specimens from consecutively diagnosed smear-positive tuberculosis patients were tested with OraQuick® and 2 HIV-1/2 ELISA's. Sputum was tested within 24 hours of collection, split into 2 aliquots with and without addition of cetylpyridium chloride, and tested again after 4 and 7 days. Results: Complete data was available for 377/435 (87%) enrolled patients; 132 (35%) tested HIV positive on serum. The sensitivity of the sputum test was 94.7% (95% CI 89.4–97.8) on day 1, 93.2% on day 4 and 92.9% on day 7. The specificity was 92.9% (95% CI 88.9–95.8) on day 1, and declined to 76.7% on day 4 (p < 0.001) and to 62.7% on day 7 (p < 0.001). Adding cetylpyridium chloride further decreased the specificity to 67.8% on day 4 (p = 0.04) and to 49.6% on day 7 (p = 0.004). Conclusion: Transportation of sputum specimens at ambient temperatures for 4 days or more, and addition of decontaminant, strongly affect the specificity of the OraQuick® assay. Unless applied within one day, this assay is not suitable for estimation of HIV-prevalence among tuberculosis patients in survey settings.en_GB
dc.identifier.citationEgwaga, S. M., Chonde, T. M., Matee, M. I., Mfinanga, S. G., Ngowi, P. E., Lwilla, F., & Cobelens, F. G. (2007). Low specificity of HIV-testing on sputum specimens kept at ambient temperatures for 4 to 7 days: a blinded comparison. BMC clinical pathology, 7(1), 8.
dc.identifier.issn1472-6890-7-8
dc.identifier.otherdoi:10.1186/1472-6890-7-8
dc.identifier.urihttp://hdl.handle.net/123456789/415
dc.language.isoenen_GB
dc.publisherBioMed Centralen_GB
dc.relation.ispartofseriesBMC Clinical Pathology.7:8
dc.subjectHIV-testingen_GB
dc.subjectsputumen_GB
dc.subjectambienten_GB
dc.titleLow specificity of HIV-testing on sputum specimens kept at ambient temperatures for 4 to 7 days: a blinded comparisonen_GB
dc.typeArticleen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1472-6890-7-8.pdf
Size:
227.99 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.6 KB
Format:
Item-specific license agreed upon to submission
Description: