Evaluation of the Performance of Copper Sulphate and Hemocue Methods for Haemoglobin Estimation among Blood Donors in Dar Es Salaam, Tanzania.

dc.contributor.authorKamori, D.
dc.contributor.authorMwanga, G.
dc.contributor.authorChamba, C.
dc.date.accessioned2025-03-08T08:46:46Z
dc.date.available2025-03-08T08:46:46Z
dc.date.issued2023
dc.description.abstractABSTRACT Background: The National Blood Transfusion Service (NBTS) in Tanzania uses the Copper Sulphate (CuSO4) gravimetric method to estimate hemoglobin (Hb) in blood donors. However, this and other point-of-care methods, including HemoCue, may provide false results. Therefore, this study aimed to evaluate the performance of CuSO4 and HemoCue methods for Hb estimation compared with automated hematology analyzer (AHA). Methods: The cross-sectional study was conducted among (N=204) blood donors in Dar es Salaam. Capillary blood samples were obtained for Hb estimation by CuSO4 and HemoCue methods, 3 mls of venous blood were also collected for Hb quantification by AHA (gold standard), HemoCue and CuSO4 gravimetric method. Data were analyzed by Epi info 7.2.2.6, statistical significance was defined at a P value of <0.05, and kappa agreement was calculated. Results: The median age of the study participants was 30 years (IQR: 20-39). The proportion of false eligible donors was 19.6%, and false deferral donors were 2.9% by the CuSO4 gravimetric method. The specificity, sensitivity, positive and negative predictive values, and Kappa agreement for CuSO4 were 28.6%, 95.9%, 78.0%, 72.7%, and 0.1, respectively. In contrast, the specificity, sensitivity, positive and negative predictive values, and Kappa agreement for HemoCue were 62.5%, 98.6%, 87.4%, 94.6%, and 0.63, respectively. Conclusion: Our study revealed that the performance of the CuSO4 gravimetric method in Tanzania is relatively poor, with a high proportion of false eligible donors than the HemoCue method. These findings warrant further studies to evaluate the quality control measures for CuSO4 gravimetric method and explore alternative point-of-care methods for Hb estimation among blood donors in similar resource limited-settings.en_US
dc.identifier.citation1. Kamori, D., Mwanga, G., Chamba, C., et al… (2023). Evaluation of the Performance of Copper Sulphate and Hemocue Methods for Haemoglobin Estimation among Blood Donors in Dar Es Salaam, Tanzania. East Africa Science. Vol.5 (1). Doi:10.24248/easci.v5i1.80en_US
dc.identifier.urihttp://dspace.muhas.ac.tz:8080/xmlui/handle/123456789/3430
dc.language.isoenen_US
dc.subjectCopper Sulphateen_US
dc.subjectHemocueen_US
dc.subjectHaemoglobin Estimationen_US
dc.subjectBlood Donorsen_US
dc.titleEvaluation of the Performance of Copper Sulphate and Hemocue Methods for Haemoglobin Estimation among Blood Donors in Dar Es Salaam, Tanzania.en_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kamori, D. (2023).pdf
Size:
302.94 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: