The diagnostic value of fine needle aspiration cytology for prostate lesions at muhimbili national hospital
| dc.contributor.author | Mponji, Josephat Philip | |
| dc.date.accessioned | 2013-09-03T08:39:19Z | |
| dc.date.available | 2013-09-03T08:39:19Z | |
| dc.date.issued | 2007 | |
| dc.description.abstract | This crossectional descriptive study was designed to determine the diagnostic value of FNAC, as compared to Tm Cut biopsy, a method considered as the gold standard for tissue diagnosis for prostate lesions at MNH~ Patients suspected to have cancer of the prostate from abnormal DRE such as nodular, hard, irregular enlarged prostate or from high levels of PSA (4.Ong/ml or more) or from ultrasonography of hypo echoic lesion(s) or having any combination of the three, were included after their voluntary consent had been obtained. They had both FNAC and Tm Cut biopsies performed at the same sitting, FNAC preceded Tm Cut biopsy always. Smears made at FNAC were fixed in 95% alcohol while the core biopsy specimens were preserved in formalin, and both were labeled and submitted to the pathology laboratory. A specific cytologist was given FNAC specimen to interpret while histology specimen where sent to other pathologists so as to avoid bias at reporting results. A total of 119 patients met the inclusion criteria for the study between first date of March and the last date of December 2006. One hundreds and ten patients (92%) enrolled into the study had PSA levels more than 4 ng/ml ,thirty two patients enrolled had hypo echoic lesion at ultrasonography and of the enrolled patients grade three prostate enlargement was found in 76(63.9%). Cancer was diagnosed by histology in 57(47.9%) patients as compared to 50(42%) cancer diagnoses by cytology. The age most commonly affected by cancer when the gold standard (core needle) biopsy when used was 60-69 years. Cancer of prostate was uncommon in patients below 60 years.The accuracy of FNAC diagnosis for prostate lesions when compared with histological diagnosis as standard test was calculated from 101 patients who had adequate specimens for comparison. A total of 18 patients had inadequate specimen of which 11 had inadequate cytology and 7 had inadequate histology were not included at calculating the accuracy. Thirty eight cases were found to have True Positive (TP) cancer diagnoses , 41 patients had True Negative (TN) results,12 patients had false negative (FN)results and 10 patients had False positive (FP)results for prostate cancer diagnosis .The sensitivity of FNAC was found to be 76%, specificity of FNAC was 80.3%, positive predictive value (PPV) was 79.2%, negative predictive value (NPV) of FNAC was 77.4% and the overall accuracy of FNAC in study was 78.2% The use of FNAC had an overall cost reduction of more than 77.5% of the cost core needle biopsy. When under optimal conditions FNAC would minimize the duration to obtain tissue diagnosis results for about 97% of the duration required for histology diagnosis .The fact that some prostate cancer patients are severely anemic, therefore a more invasive procedure such as core biopsy would worsen the pre existing anemia, this may be avoided by using FNAC instead Fine needle aspiration of the prostate should be introduced at MNH and prostate aspiration procedures should be part of training for medical doctors in surgery and histopathology. Also systematic sampling of the prostate should also be introduced so as to increase the diagnostic accuracy of core needle biopsy. | en_GB |
| dc.identifier.uri | http://hdl.handle.net/123456789/1133 | |
| dc.language.iso | en | en_GB |
| dc.publisher | Muhimbili University of Health and Allied Sciences | |
| dc.subject | diagnostic value | en_GB |
| dc.subject | Aspiration cytology | en_GB |
| dc.subject | prostate lesions | en_GB |
| dc.title | The diagnostic value of fine needle aspiration cytology for prostate lesions at muhimbili national hospital | en_GB |
| dc.type | Thesis | en_GB |
